The '''boiling point''' of a liquid is the [[temperature]] at which the [[vapor pressure]] of the liquid equals the external environmental [[pressure]] surrounding the liquid. The boiling point of a liquid may also be defined as the temperature at which it changes its state from a liquid to a gas throughout the bulk of the liquid. At that point, bubbles of vapor which form below the surface of the liquid contain vapor at a pressure which matches the external pressure. Therefore, they are not crushed by the surrounding liquid and their bouyancy causes them to rise through to the surface of the liquid and give the familiar appearance of a boiling liquid.<ref>[http://msds.chem.ox.ac.uk/glossary/boiling_point.html Glossary (website of the chemistry department at Oxford University)]</ref><ref>{{cite book|author=Edward W. Washburn|title=An Introduction to the Principles of Physical Chemistry|edition=First Edition|publisher=McGraw-Hill|year=1915|pages=page 55|id=Library of Congress Control No. 15024872}}</ref>
{{AccountNotLive}}
__NOTOC__
[[File:Crude oil-fired power plant.jpg|thumb|right|225px|Industrial air pollution source]]
Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.  


A liquid in a vacuum environment has a lower boiling point than when the liquid is at [[atmospheric pressure]]. A liquid in a high pressure environment has a higher boiling point than when the liquid is at atmospheric pressure. In other words, the boiling point of a liquid varies with and depends upon the surrounding environmental pressure.
Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.<ref>J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", ''JAPCA'', Vol. 21, No. 7, 1971.</ref> 


The '''normal boiling point''' (also called the '''atmospheric boiling point''' or the '''atmospheric pressure boiling point''') of a liquid is the special case in which the vapor pressure of the liquid equals 101.325 [[Pascal (unit)|kilopascals]] (kPa).<ref>[http://goldbook.iupac.org/N04211.html IUPAC Recommendations 1994 (page 537)]</ref><ref>{{cite book|author=David R. Lide (Editor)|title=CRC Handbook of Chemistry and Physics|edition=85th Edition|publisher=CRC Press|year=2004|pages=page 3-1|id=ISBN 0-8493-0485-7}}</ref>
Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.


The [[heat of vaporization]] is the amount of [[heat]] required to convert or vaporize a saturated liquid (i.e., a liquid at its boiling point) into a vapor.
The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:


Liquids may change to a vapor at temperatures below their boiling points through the process of [[evaporation]]. Evaporation is a surface phenomenon in which molecules located near the vapor/liquid surface escape into the vapor phase. On the other hand, boiling is a process in which molecules anywhere in the liquid escape, resulting in the formation of vapor bubbles within the liquid.
* Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
* The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
* Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
* The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).


== Saturation temperature and pressure==
Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.


A '''saturated liquid''' contains as much thermal energy (i.e., heat) as it can without boiling and, conversely, a '''saturated vapor''' contains as little thermal energy as it can without [[Condensation|condensing]].
The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.


The term '''saturation temperature''' means ''boiling point'' and it is the temperature for a corresponding saturation pressure at which a liquid boils into its vapor phase. The liquid can be said to be saturated with thermal energy. Any addition of thermal energy results in a phase change.
==Atmospheric layers==


If the pressure in a system remains constant (i.e., the system is [[Isobaric process|isobaric]]), a vapor at saturation temperature will begin to condense into its liquid phase as thermal energy  is removed. Similarly, a liquid at saturation temperature and pressure will boil into its vapor phase as additional thermal energy is applied.
Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the ''troposphere''. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The ''stratosphere'' is the next layer and extends from 18 km up to about 50 km. The third layer is the ''mesosphere'' which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.


As explained above, the boiling point of a liquid is dependent on the pressure. Usually, boiling points are published with respect to the atmospheric pressure (101.325 kPa or 1 [[atmosphere (unit)|atm]]) at sea level, which is also known as the ''standard atmosphere''.<ref>[http://goldbook.iupac.org/S05906.html IUPAC Goldbook definition]</ref> At higher elevations, where the atmospheric pressure is lower, the boiling point is also lower. The boiling point increases with increased pressure up to the [[critical point]], where the gas and liquid properties become identical. The boiling point cannot be increased beyond the critical point. Likewise, the boiling point decreases with decreasing pressure until the [[triple point]] is reached. The boiling point cannot be reduced below the triple point.
The lowest part of the troposphere is called the ''atmospheric boundary layer (ABL)'' or the ''planetary boundary layer (PBL)'' and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the ''inversion layer'' (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the ''free troposphere'' and it extends up to the 18 km height of the troposphere.


If the heat of vaporization and the vapor pressure of a liquid at a certain temperature is known, the normal boiling point can be calculated by using the [[Clausius-Clapeyron equation]]:<ref>{{cite book|author=John M. Seddon and Julian D. Gale|title=Thermodynamics and Statistical Mechanics|edition=|publisher=Royal Society of Chemistry|year=2001|id=ISBN 0-85404-632-1}}</ref><ref>[http://www.science.uwaterloo.ca/~cchieh/cact/c123/clausius.html The Clausius-Clapeyron Equation] (Professor Chung Chieh, University of Waterloo, Canada)</ref>
The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the ''mixing layer''. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.


In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as ''boundary layer models'' because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as ''mesoscale models'' have dispersion modeling capabilities that can extend horizontally as much as  a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.


<math>T_B = \Bigg(\frac{\,R\,[\,\ln(P_0)-\ln(101.325)\,]}{\Delta H_{vap}}+\frac{1}{T_0}\Bigg)^{-1}</math>
==Gaussian air pollutant dispersion equation==


{| border="0" cellpadding="2"
The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.<ref>C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", ''Trans. Faraday Soc.'', 32:1249, 1936.</ref> Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.
 
Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947<ref>O.G. Sutton, "The problem of diffusion in the lower atmosphere", ''QJRMS'', 73:257, 1947.</ref><ref>O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", ''QJRMS'', 73:426, 1947.</ref> which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.
 
Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the '''Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes''' shown below:<ref name=Beychok>{{cite book|author=M.R. Beychok|title=Fundamentals Of Stack Gas Dispersion|edition=4th Edition| publisher=author-published|year=2005|isbn=0-9644588-0-2}}.</ref><ref>{{cite book|author=D. B. Turner| title=Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling| edition=2nd Edition |publisher=CRC Press|year=1994|isbn=1-56670-023-X}}.</ref>
 
 
<math>C = \frac{\;Q}{u}\cdot\frac{\;f}{\sigma_y\sqrt{2\pi}}\;\cdot\frac{\;g_1 + g_2 + g_3}{\sigma_z\sqrt{2\pi}}</math>
 
{| border="0" cellpadding="2"  
|-
|-
|align=right|where:
|align=right|where:
|&nbsp;
|&nbsp;
|-
|-
!align=right|<math>T_B</math>   
!align=right|<math>f</math>   
|align=left|= the normal boiling point, K
|align=left|= crosswind dispersion parameter
|-
!align=right|&nbsp;
|align=left|= <math>\exp\;[-\,y^2/\,(2\;\sigma_y^2\;)\;]</math>
|-
!align=right|<math>g</math>
|align=left|= vertical dispersion parameter = <math>\,g_1 + g_2 + g_3</math>
|-
!align=right|<math>g_1</math>
|align=left|= vertical dispersion with no reflections
|-
!align=right|&nbsp;
|align=left|= <math>\; \exp\;[-\,(z - H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_2</math>
|align=left|= vertical dispersion for reflection from the ground
|-
!align=right|&nbsp;
|align=left|= <math>\;\exp\;[-\,(z + H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_3</math>
|align=left|= vertical dispersion for reflection from an inversion aloft
|-
!align=right|&nbsp;
|align=left|= <math>\sum_{m=1}^\infty\;\big\{\exp\;[-\,(z - H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z - H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]\big\}</math>
|-
!align=right|<math>C</math>
|align=left|= concentration of emissions, in g/m³, at any receptor located:
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; x meters downwind from the emission source point
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; y meters crosswind from the emission plume centerline
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; z meters above ground level
|-
!align=right|<math>Q</math>
|align=left|= source pollutant emission rate, in g/s
|-
|-
!align=right|<math>R</math>  
!align=right|<math>u</math>
|align=left|= the [[ideal gas constant]], 8.314 J · K<sup>-1</sup> · mol<sup>-1</sup>
|align=left|= horizontal wind velocity along the plume centerline, m/s
|-
|-
!align=right|<math>P_0</math>
!align=right|<math>H</math>
|align=left|= is the vapor pressure at a given temperature, kPa
|align=left|= height of emission plume centerline above ground level, in m
|-
|-
!align=right| <math>101.325</math>
!align=right|<math>\sigma_z</math>
|align=left|= atmospheric pressure, kPa
|align=left|= vertical standard deviation of the emission distribution, in m
|-
|-
!align=right|<math>\Delta H_{vap} </math>
!align=right|<math>\sigma_y</math>
|align=left|= the heat of vaporization of the liquid, J/mol
|align=left|= horizontal standard deviation of the emission distribution, in m
|-
|-
!align=right|<math>T_0</math>
!align=right|<math>L</math>
|align=left|= the given temperature, K
|align=left|= height from ground level to bottom of the inversion aloft, in m
|-
|-
!align=right|<math>ln</math>
!align=right|<math>\exp</math>
|align=left|= the [[natural logarithm]] to the base [[e]]
|align=left|= the exponential function
|}
|}


'''Saturation pressure''' is the pressure for a corresponding saturation temperature at which a liquid boils into its vapor phase. Saturation pressure and saturation temperature have a direct relationship: as saturation pressure is increased so is saturation temperature.
The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.
 
The sum of the four exponential terms in <math>g_3</math> converges to a final value quite rapidly. For most cases, the summation of the series with '''''m''''' = 1, '''''m''''' = 2 and '''''m''''' = 3 will provide an adequate solution.


If the temperature in a [[system]] remains constant (an ''[[isothermal]]'' system), vapor at saturation pressure and temperature will begin to [[condensation|condense]] into its liquid phase as the system pressure is increased. Similarly, a liquid at saturation pressure and temperature will tend to [[Flash evaporation|flash]] into its vapor phase as system pressure is decreased.
<math>\sigma_z</math> and <math>\sigma_y</math> are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.


The boiling point of [[water]] is 100&nbsp;[[Celsius|°C]] (212&nbsp;[[Fahrenheit|°F]]) at standard pressure. On top of [[Mount Everest]] the pressure is about 260 [[Millibar|mbar]] (26.39 kPa) so the boiling point of water is 69&nbsp;[[Celsius|°C]]. (156.2&nbsp;[[Fahrenheit|°F]]).
Whereas older models rely on stability classes for the determination of <math>\sigma_y</math> and <math>\sigma_z</math>, more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.


For purists, the ''normal boiling point of water'' is 99.97 degrees Celsius at a pressure of 1 atm (i.e., 101.325 kPa). Until 1982 this was also the ''standard boiling point of water'', but the [[IUPAC]] now recommends a standard pressure of 1 bar (100 kPa). At this slightly reduced pressure, the ''standard boiling point of water'' is 99.61 degrees Celsius.
==Briggs plume rise equations==


==Relation between the normal boiling point and the vapor pressure of liquids ==
The Gaussian air pollutant dispersion equation (discussed above) requires the input of ''H'' which is the pollutant plume's centerline height above ground level. ''H'' is the sum of ''H''<sub>s</sub> (the actual physical height of the pollutant plume's emission source point) plus Δ''H'' (the plume rise due the plume's buoyancy).


[[Image:Vapor Pressure Chart.png|thumb|right|301 px|A typical vapor pressure chart for various liquids]]
[[File:Gaussian Plume.png|thumb|right|333px|Visualization of a buoyant Gaussian air pollutant dispersion plume]]


The higher the vapor pressure of a liquid at a given temperature, the lower the normal boiling point (i.e., the boiling point at atmospheric pressure) of the liquid.
To determine Δ''H'', many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.<ref>G.A. Briggs, "A plume rise model compared with observations", ''JAPCA'', 15:433–438, 1965.</ref> In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.<ref>G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", ''Atmos. Envir.'', 2:228–232, 1968.</ref> In that same year, Briggs also wrote the section of the publication edited by Slade<ref>D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.</ref> dealing with the comparative analyses of plume rise models.  That was followed in 1969 by his classical critical review of the entire plume rise literature,<ref>G.A. Briggs, "Plume Rise", ''USAEC Critical Review Series'', 1969.</ref> in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations".  Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.<ref>G.A. Briggs, "Some recent analyses of plume rise observation", ''Proc. Second Internat'l. Clean Air Congress'', Academic Press, New York, 1971.</ref><ref>G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", ''Atmos. Envir.'', 6:507–510, 1972.</ref>


The vapor pressure chart to the right has graphs of the vapor pressures versus temperatures for a variety of liquids.<ref>{{cite book|author=Perry, R.H. and Green, D.W. (Editors)|title=[[Perry's  Chemical Engineers' Handbook]]|edition=7th Edition|publisher=McGraw-Hill|year=1997|id= ISBN 0-07-049841-5}}</ref> As can be seen in the chart, the liquids with the highest vapor pressures have the lowest normal boiling points.
Briggs divided air pollution plumes into these four general categories:
* Cold jet plumes in calm ambient air conditions
* Cold jet plumes in windy ambient air conditions
* Hot, buoyant plumes in calm ambient air conditions
* Hot, buoyant plumes in windy ambient air conditions


For example, at any given temperature, [[propane]] has the highest vapor pressure of any of the liquids in the chart. It also has the lowest normal boiling point(-43.7 °C), which is where the vapor pressure curve of propane (the purple line) intersects the horizontal pressure line of one atmosphere ([[Atmosphere (unit)|atm]]) of absolute vapor pressure.
Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant. Although Briggs proposed plume rise equations for each of the above plume categories, '''''it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes'''''.


In terms of [[intermolecular]] interactions, the boiling point represents the point at which the liquid [[molecules]] possess enough [[thermal energy]] to overcome the various intermolecular attractions binding the molecules into the liquid (eg. [[dipole-dipole attraction]], [[instantaneous-dipole induced-dipole attraction]]s, and [[hydrogen bond]]s). Therefore the boiling point is also an indicator of the strength of these attractive forces.
In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants.  Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).
 
A logic diagram for using the Briggs equations<ref name=Beychok/> to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:
[[Image:BriggsLogic.png|none]]
:{| border="0" cellpadding="2"
|-
|align=right|where:
|&nbsp;
|-
!align=right| Δh
|align=left|= plume rise, in m
|-
!align=right| F<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->
|align=left|= buoyancy factor, in m<sup>4</sup>s<sup>−3</sup>
|-
!align=right| x
|align=left|= downwind distance from plume source, in m
|-
!align=right| x<sub>f</sub>
|align=left|= downwind distance from plume source to point of maximum plume rise, in m
|-
!align=right| u
|align=left|= windspeed at actual stack height, in m/s
|-
!align=right| s<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->
|align=left|= stability parameter, in s<sup>−2</sup>
|}
The above parameters used in the Briggs' equations are discussed in Beychok's book.<ref name=Beychok/>


==References==
==References==
{{reflist}}
== Further reading==
*{{cite book | author=M.R. Beychok| title=Fundamentals Of Stack Gas Dispersion | edition=4th Edition | publisher=author-published | year=2005 | isbn=0-9644588-0-2}}
*{{cite book | author=K.B. Schnelle and P.R. Dey| title=Atmospheric Dispersion Modeling Compliance Guide  | edition=1st Edition| publisher=McGraw-Hill Professional | year=1999 | isbn=0-07-058059-6}}
*{{cite book | author=D.B. Turner| title=Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling | edition=2nd Edition | publisher=CRC Press | year=1994 | isbn=1-56670-023-X}}


{{reflist}}
*{{cite book | author= S.P. Arya| title=Air Pollution Meteorology and Dispersion | edition=1st Edition | publisher=Oxford University Press | year=1998 | isbn=0-19-507398-3}}
 
*{{cite book | author=R. Barrat| title=Atmospheric Dispersion Modelling | edition=1st Edition | publisher=Earthscan Publications | year=2001 | isbn=1-85383-642-7}}
 
*{{cite book | author=S.R. Hanna and R.E. Britter| title=Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites  | edition=1st Edition | publisher=Wiley-American Institute of Chemical Engineers | year=2002 | isbn=0-8169-0863-X}}
 
*{{cite book | author=P. Zannetti| title=Air pollution modeling : theories, computational methods, and available software | edition= | publisher= Van Nostrand Reinhold | year=1990 | isbn=0-442-30805-1 }}

Latest revision as of 04:25, 22 November 2023


The account of this former contributor was not re-activated after the server upgrade of March 2022.


Industrial air pollution source

Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.

Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.[1]

Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.

The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:

  • Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
  • The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
  • Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
  • The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).

Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.

The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.

Atmospheric layers

Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the troposphere. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The stratosphere is the next layer and extends from 18 km up to about 50 km. The third layer is the mesosphere which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.

The lowest part of the troposphere is called the atmospheric boundary layer (ABL) or the planetary boundary layer (PBL) and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the inversion layer (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the free troposphere and it extends up to the 18 km height of the troposphere.

The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the mixing layer. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.

In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as boundary layer models because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as mesoscale models have dispersion modeling capabilities that can extend horizontally as much as a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.

Gaussian air pollutant dispersion equation

The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.[2] Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.

Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947[3][4] which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.

Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes shown below:[5][6]


where:  
= crosswind dispersion parameter
  =
= vertical dispersion parameter =
= vertical dispersion with no reflections
  =
= vertical dispersion for reflection from the ground
  =
= vertical dispersion for reflection from an inversion aloft
  =
           
           
           
= concentration of emissions, in g/m³, at any receptor located:
            x meters downwind from the emission source point
            y meters crosswind from the emission plume centerline
            z meters above ground level
= source pollutant emission rate, in g/s
= horizontal wind velocity along the plume centerline, m/s
= height of emission plume centerline above ground level, in m
= vertical standard deviation of the emission distribution, in m
= horizontal standard deviation of the emission distribution, in m
= height from ground level to bottom of the inversion aloft, in m
= the exponential function

The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.

The sum of the four exponential terms in converges to a final value quite rapidly. For most cases, the summation of the series with m = 1, m = 2 and m = 3 will provide an adequate solution.

and are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.

Whereas older models rely on stability classes for the determination of and , more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.

Briggs plume rise equations

The Gaussian air pollutant dispersion equation (discussed above) requires the input of H which is the pollutant plume's centerline height above ground level. H is the sum of Hs (the actual physical height of the pollutant plume's emission source point) plus ΔH (the plume rise due the plume's buoyancy).

Visualization of a buoyant Gaussian air pollutant dispersion plume

To determine ΔH, many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.[7] In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.[8] In that same year, Briggs also wrote the section of the publication edited by Slade[9] dealing with the comparative analyses of plume rise models. That was followed in 1969 by his classical critical review of the entire plume rise literature,[10] in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations". Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.[11][12]

Briggs divided air pollution plumes into these four general categories:

  • Cold jet plumes in calm ambient air conditions
  • Cold jet plumes in windy ambient air conditions
  • Hot, buoyant plumes in calm ambient air conditions
  • Hot, buoyant plumes in windy ambient air conditions

Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant. Although Briggs proposed plume rise equations for each of the above plume categories, it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes.

In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants. Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).

A logic diagram for using the Briggs equations[5] to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:

BriggsLogic.png
where:  
Δh = plume rise, in m
F  = buoyancy factor, in m4s−3
x = downwind distance from plume source, in m
xf = downwind distance from plume source to point of maximum plume rise, in m
u = windspeed at actual stack height, in m/s
s  = stability parameter, in s−2

The above parameters used in the Briggs' equations are discussed in Beychok's book.[5]

References

  1. J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", JAPCA, Vol. 21, No. 7, 1971.
  2. C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", Trans. Faraday Soc., 32:1249, 1936.
  3. O.G. Sutton, "The problem of diffusion in the lower atmosphere", QJRMS, 73:257, 1947.
  4. O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", QJRMS, 73:426, 1947.
  5. 5.0 5.1 5.2 M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. .
  6. D. B. Turner (1994). Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. .
  7. G.A. Briggs, "A plume rise model compared with observations", JAPCA, 15:433–438, 1965.
  8. G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", Atmos. Envir., 2:228–232, 1968.
  9. D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.
  10. G.A. Briggs, "Plume Rise", USAEC Critical Review Series, 1969.
  11. G.A. Briggs, "Some recent analyses of plume rise observation", Proc. Second Internat'l. Clean Air Congress, Academic Press, New York, 1971.
  12. G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", Atmos. Envir., 6:507–510, 1972.

Further reading

  • M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. 
  • K.B. Schnelle and P.R. Dey (1999). Atmospheric Dispersion Modeling Compliance Guide, 1st Edition. McGraw-Hill Professional. ISBN 0-07-058059-6. 
  • D.B. Turner (1994). Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. 
  • S.P. Arya (1998). Air Pollution Meteorology and Dispersion, 1st Edition. Oxford University Press. ISBN 0-19-507398-3. 
  • R. Barrat (2001). Atmospheric Dispersion Modelling, 1st Edition. Earthscan Publications. ISBN 1-85383-642-7. 
  • S.R. Hanna and R.E. Britter (2002). Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites, 1st Edition. Wiley-American Institute of Chemical Engineers. ISBN 0-8169-0863-X. 
  • P. Zannetti (1990). Air pollution modeling : theories, computational methods, and available software. Van Nostrand Reinhold. ISBN 0-442-30805-1.