There must be a source of neutrons. For some applications, this must be a full-sized [[nuclear reactor]], with all the associated safety and cost consideration.  Portable sources, however, work for some applications.
There must be a source of neutrons. For some applications, this must be a full-sized [[nuclear reactor]], with all the associated safety and cost consideration.  Portable sources, however, work for some applications.
==Major facilities==
==Major facilities==
One major NAA research facility is the [[High Flux Isotope Reactor]] at [[Oak Ridge National Laboratory]].<ref>{{citation
Having a nuclear reactor is a prerequisite for the most extensive analytical service, as well as research into NAA. These include:
*[[High Flux Isotope Reactor]] at [[Oak Ridge National Laboratory]].<ref>{{citation
  | url = http://neutrons.ornl.gov/facilities/HFIR/naa.shtml
  | url = http://neutrons.ornl.gov/facilities/HFIR/naa.shtml
  | title = What is Neutron Activation Analysis?
  | title = What is Neutron Activation Analysis?
  | publisher = Neutron Sciences, [[Oak Ridge National Laboratory]]}}</ref>
  | publisher = Neutron Sciences, [[Oak Ridge National Laboratory]]}}</ref>
*Nuclear Reactor Laboratory, [[University of Wisconsin]]
==Applications==
==Applications==
===Explosives===
===Explosives===
Line 48: Line 50:


They form part of [[mine (land warfare)|land mine]] detection systems, working on the explosive or a plastic casing not sensed by a metal detector.  
They form part of [[mine (land warfare)|land mine]] detection systems, working on the explosive or a plastic casing not sensed by a metal detector.  
===Forensics===
NAA has significant potential in its use in legal forensic, but it must be presented in proper context. From the legal standpoint, <blockquote>the interpretation of the analysis presents difficult legal problems that depend almost entirely on the circumstances of the individual case. The analytical chemist is qualified to present the results of the analysis, but his subjective interpretation, as a chemist, is worthless; an expert in statistics is required to present a legal interpretation of the analysis. The expert must have a solid, objective basis for any statement beyond the composition of the measured samples, and the burden of laying an objective foundation for the testimony should rest on the party seeking to introduce the results of the tests. The expert must use well-defined terms which fit the legal issue presented by the facts of the case, and must present his testimony in such a way that the trier of fact clearly understands the limitations of the analysis. <ref>{{citation
| title = Comment, the Evidentiary Uses of Neutron  Activation Analysis
| author = Dennis S. Karjala
| journal = California Law Review
| url = http://papers.ssrn.com/sol3/papers.cfm?abstract_id=1438160
| volume = 59}} p. 997, 1971 </ref></blockquote>
==References==
==References==
{{reflist|2}}
{{reflist|2}}

Revision as of 07:47, 17 May 2010

This article is a stub and thus not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This editable Main Article is under development and subject to a disclaimer.

Neutron activation analysis (NAA) is an extremely sensitive technique of radiochemical analysis used to determine the existence and quantities of major, minor and trace elements in a material sample. As opposed to other methods in analytical chemistry, such as mass spectrometry or chromatography, it focuses entirely on the nuclei of atoms, not their molecular structure. It reports the concentrations of all elements in a sample, down to extremely low levels.

Principles

When samples are irradiated with neutrons, certain of their elements become radioactive, and emit gamma rays of various energies. "This emitted radiation is a 'fingerprint' of the element, and the amount of radiation given off at a certain energy is indicative of the amount of the element present in the sample. A comparison between specific activities induced in the standards and unknowns provides the basis for computation of elemental abundances. From this analysis, a report is issued giving elemental concentrations in the unknown sample."[1]

The above description implies a measurement at a single point in time. Taking multiple measurements, of "prompt" and "delayed" gamma emission, adds another dimension. Two given elements might emit gammas of the same energy, but since the radioactive isotopes have different half-lives, one will stop emitting before the other.

Applicability

Not all elements absorb neutrons in a manner that makes them detectable by NAA, but approximately 65 do.

Table goes here

Some of these can be further differentiated by prompt and delayed NAA.

Table goes here

Comparison with other methods

Advantages

  • Inherently nondestructive. "The sample is not permanently damaged by NAA, and in the case case of forensic analysis and analysis of rare samples, such as meteorites or archeological finds, the sample can be saved and even subjected to further analysis at a later time...the sample may become slightly radioactive in NAA, the radiation in the sample decreases with time until it reaches a state similar to which it was before the NAA was performed on it."
  • "detects the total elemental content, regardless of oxidation state, chemical form or physical location." [2]
  • Simultaneously detects all elements in the sample
  • Time-efficient for analyzing many samples

Disadvantages

There must be a source of neutrons. For some applications, this must be a full-sized nuclear reactor, with all the associated safety and cost consideration. Portable sources, however, work for some applications.

Major facilities

Having a nuclear reactor is a prerequisite for the most extensive analytical service, as well as research into NAA. These include:

Applications

Explosives

By examining both ratios of major elements (e.g., carbon, hydrogen, oxygen, nitrogen) as well as the presence of trace elements, NAA, even though explosives are molecules, has been able both to trace the source of explosions after detonation, as well as nondestructively tracing the manufacturer of explosives in situ. [4] NAA has been useful, in like manner, in tracing chemical warfare agents and nuclear materials.

Reference standards are being developed by the National Institute of Standards and Technology. [5], with available samples for RDX, TNT and HMX.

They form part of land mine detection systems, working on the explosive or a plastic casing not sensed by a metal detector.

Forensics

NAA has significant potential in its use in legal forensic, but it must be presented in proper context. From the legal standpoint,

the interpretation of the analysis presents difficult legal problems that depend almost entirely on the circumstances of the individual case. The analytical chemist is qualified to present the results of the analysis, but his subjective interpretation, as a chemist, is worthless; an expert in statistics is required to present a legal interpretation of the analysis. The expert must have a solid, objective basis for any statement beyond the composition of the measured samples, and the burden of laying an objective foundation for the testimony should rest on the party seeking to introduce the results of the tests. The expert must use well-defined terms which fit the legal issue presented by the facts of the case, and must present his testimony in such a way that the trier of fact clearly understands the limitations of the analysis. [6]

References

  1. Neutron Activation Analysis Description, Nuclear Reactor Laboratory, University of Wisconsin
  2. Advantages of NAA over other chemical analyses, Nuclear Reactor Laboratory, University of Wisconsin
  3. What is Neutron Activation Analysis?, Neutron Sciences, Oak Ridge National Laboratory
  4. Nunes WV, da Silva AX, Crispim VR, Schirru R (2002 Jun), "Explosives detection using prompt-gamma neutron activation and neural networks.", Appl Radiat Isot. 56(6): 937-43.
  5. Development of NIST Standard Reference Materials for Trace Explosives Detection, National Institute of Standards and Technology
  6. Dennis S. Karjala, "Comment, the Evidentiary Uses of Neutron Activation Analysis", California Law Review 59 p. 997, 1971