Open loop control: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Hendra I. Nurdin
m (Wording change, inserted link to closed loop control)
imported>Subpagination Bot
m (Add {{subpages}} and remove any categories (details))
Line 1: Line 1:
{{subpages}}
In [[control engineering]], '''open loop control''' is a [[control system]] configuration in which the controller is restricted to have no access to signals which contain additional information about the current "state" of the plant (the object or system to be controlled) during the time that the controller is in operation. Here state roughly refers to a collection of dynamical variables of the plant which determine the plant's future evolution/trajectory given its future inputs.  
In [[control engineering]], '''open loop control''' is a [[control system]] configuration in which the controller is restricted to have no access to signals which contain additional information about the current "state" of the plant (the object or system to be controlled) during the time that the controller is in operation. Here state roughly refers to a collection of dynamical variables of the plant which determine the plant's future evolution/trajectory given its future inputs.  


Line 8: Line 10:


[[Closed loop control]]
[[Closed loop control]]
[[Category:Engineering_Workgroup]]
[[Category:CZ Live]]

Revision as of 07:56, 12 November 2007

This article is a stub and thus not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This editable Main Article is under development and subject to a disclaimer.

In control engineering, open loop control is a control system configuration in which the controller is restricted to have no access to signals which contain additional information about the current "state" of the plant (the object or system to be controlled) during the time that the controller is in operation. Here state roughly refers to a collection of dynamical variables of the plant which determine the plant's future evolution/trajectory given its future inputs.

In open loop control, the control law implemented by the controller at any time is independent of the dynamical variables of the plant. In practice, this situation may arise in, for example, cases where it is not feasible or practical to extract any useful information from the plant that can be used for control purposes. In designing a controller for open loop control, the control engineer would need to have a good mathematical model of the plant to be able to derive a control law which achieves the desired performance specifications. A major drawback of open loop control compared to closed loop control is that deviations of the model from the true plant and the presence of various exogenous disturbances may result in serious degradation of the performance of the overall control system (i.e. the plant with the controller attached). In this case it is said that open loop control systems lack robustness.

A more recent example of open loop control can be found in the quantum control of spin systems using pulsed NMR techniques [1].

See also

Closed loop control