{| class = "wikitable" align="center"
{| class = "wikitable" align="center"
|+ Examples of Proximate and Ultimate Analyses<ref>{{cite book|author=Chris Higman and Maarten van der Burgt|title=Coal Gasification|edition=2nd Edition|publisher=Gulf Professional Publishers|year=2008|id=ISBN 0-7506-8528-X}}</ref>
|+ Examples of Proximate and Ultimate Analyses <ref>{{cite book|author=Chris Higman and Maarten van der Burgt|title=Coal Gasification|edition=2nd Edition|publisher=Gulf Professional Publishers|year=2008|id=ISBN 0-7506-8528-X}}</ref>
!colspan="2"|<br>Coal||colspan="4"|Proximate Analyisis<br>(wt % ar)<sup> (a)</sup>||colspan="5"|Ultimate Analysis<br>(wt % maf)<sup> (a)</sup>||rowspan=2|Net<br>Heating<br>Value<br>(maf)<br>(MJ/kg)
!rowspan="2"|<br><br><br><br>Coal Rank||colspan="4"|Proximate Analysis<br>(wt % ar) ||colspan="5"|Ultimate Analysis<br>(wt % maf)||rowspan=2|Net<br>Heating<br>Value<br>(maf)<br>(MJ/kg)
|- align="center"
|- align="center"
!<br>Country||<br>Rank||Fixed<br>carbon||Volatile<br>matter||<br>Moisture ||<br>Ash ||<br>C||<br>H||<br>O||<br>N||<br>S
!Fixed<br>carbon||Volatile<br>matter||<br>Moisture ||<br>Ash ||<br>C||<br>H||<br>O||<br>N||<br>S
|-
|-
|Germany||Anthracite||align="center"|81.8||align="center"|7.7||align="center"|4.5||align="center"|6.0||align="center"|91.8||align="center"|3.6||align="center"|2.5||align="center"|1.4||align="center"|0.7||align="center"|36.2
|Anthracite||align="center"|81.8||align="center"|7.7||align="center"|4.5||align="center"|6.0||align="center"|91.8||align="center"|3.6||align="center"|2.5||align="center"|1.4||align="center"|0.7||align="center"|36.2
|-
|-
|Poland||Bituminous||align="center"|54.9||align="center"|35.6||align="center"|5.3||align="center"|4.2||align="center"|82.8||align="center"|5.1||align="center"|10.1||align="center"|1.4||align="center"|0.6||align="center"|36.1
|Bituminous||align="center"|54.9||align="center"|35.6||align="center"|5.3||align="center"|4.2||align="center"|82.8||align="center"|5.1||align="center"|10.1||align="center"|1.4||align="center"|0.6||align="center"|36.1
|-
|-
|USA||Subbituminous||align="center"|43.6||align="center"|34.7||align="center"|110.5||align="center"|11.2||align="center"|76.4||align="center"|5.6||align="center"|14.9||align="center"|1.7||align="center"|1.4||align="center"|31.8
|Subbituminous||align="center"|43.6||align="center"|34.7||align="center"|110.5||align="center"|11.2||align="center"|76.4||align="center"|5.6||align="center"|14.9||align="center"|1.7||align="center"|1.4||align="center"|31.8
|-
|-
|USA||Lignite||align="center"|27.8||align="center"|24.9||align="center"|36.9||align="center"|10.4||align="center"|71.0||align="center"|4.3||align="center"|23.2||align="center"|1.1||align="center"|0.4||align="center"|26.7
||Lignite||align="center"|27.8||align="center"|24.9||align="center"|36.9||align="center"|10.4||align="center"|71.0||align="center"|4.3||align="center"|23.2||align="center"|1.1||align="center"|0.4||align="center"|26.7
|-
|colspan="12"|'''Notes''':<br>
• wt % = percent by weight &nbsp; &nbsp; ar = as received &nbsp; &nbsp; maf = moisture and ash free<br>
• C = Carbon &nbsp; &nbsp; H = Hydrogen &nbsp; &nbsp; O = Oxygen &nbsp; &nbsp; N = Nitrogen &nbsp; &nbsp; S = Sulfur <br>
• Multiply [[Net Heating Value]]s in M[[Joule|J]]/[[Kilogram|kg]] by 430.11 to convert to [[U.S. customary units|Btu]]/[[U.S. customary units|lb]].
|}
|}

Revision as of 21:36, 30 April 2009

Examples of Proximate and Ultimate Analyses [1]




Coal Rank
Proximate Analysis
(wt % ar)
Ultimate Analysis
(wt % maf)
Net
Heating
Value
(maf)
(MJ/kg)
Fixed
carbon
Volatile
matter

Moisture

Ash

C

H

O

N

S
Anthracite 81.8 7.7 4.5 6.0 91.8 3.6 2.5 1.4 0.7 36.2
Bituminous 54.9 35.6 5.3 4.2 82.8 5.1 10.1 1.4 0.6 36.1
Subbituminous 43.6 34.7 110.5 11.2 76.4 5.6 14.9 1.7 1.4 31.8
Lignite 27.8 24.9 36.9 10.4 71.0 4.3 23.2 1.1 0.4 26.7
Notes:

• wt % = percent by weight     ar = as received     maf = moisture and ash free
• C = Carbon     H = Hydrogen     O = Oxygen     N = Nitrogen     S = Sulfur
• Multiply Net Heating Values in MJ/kg by 430.11 to convert to Btu/lb.

  1. Chris Higman and Maarten van der Burgt (2008). Coal Gasification, 2nd Edition. Gulf Professional Publishers. ISBN 0-7506-8528-X.